UN-INTERRUPTED POWER SUPPLY [UPS]
Introduction
Continuous Supply of A.C. Power is the
lifeline of any sophisticated electronic system. Power
failuers, accidental OR from the Electricity Boards, can
waste very valuable time and corrupt the valuable data fed
in.
PACE UPS is the only remedy to overcome hazard our consequences of
BLACK-OUTS, BROWN-OUT, SAGS, SURGES SPIKES and in general all EMI / RFI
NOISES.
The
small, compact and economic way to overcome power supply problems is
PACE POWER CLEANER!
Incorporating latest in IC & solid state of art technology. |


|

Application
-
OFFICE & BUSINESS EQUIPMENTS:
Computers, Electronic Typewriters, Ledger Posting
Machines, Electronic Cash Registers, Telephone Exchanges, Fascmile
[FAX] etc.
-
CNC SYSTEM:
Photo
typesetters, teleprinters, Security systems, Process controls.
-
MEDICAL EQUIPMENTS:
Life saving emergency equipments in ICUs, X-ray
Machine, Medical Monitors, Field & Lab Instruments, Communication
Equipment etc.

Special
Features
-
Automatically switches to backup mode without power
break in zero time, ON-LINE.
-
Built-in Voltage & Frequency Stabilizer to supply
regulated 230V, 50 Hz. +/- 2%.
-
Very high isolation between Input & Output to filter
EMI /RFI.
-
Computer - grade Clean, Regulated & Filtered
continuous non - beak Power supply.
-
Automaticlly charges batteries, protected against
under / over charge.
-
Silent, sleek, compact, light weight, aesthetic
design for desk top use.
-
Ample overload capacity to handle start - up surges.
-
Maintenance free batteries.

General
Indications
|
Output on, Inverter on, Battery low
|
Alarm
|
Audible oscillating alarm on mains failure
becomes continuous 2 minutes before shutdown, alerting
battery too low.
|
Protections
|
Mains fuse, Battery fuse, Overload,
Over-charge, Under-charge, Battery polarity reversal.
|
Rating Duty
|
On Mains – Continuous On Battery –
Continuous, unlimited (Limited by Battery capacity)
|
|
Battery |
Choice of lead acid automobile battery for
easy availability, service & guarantee. |

Optional Extras
-
Battery voltage monitoring by moving coil voltmeter
-
Battery charging / discharging current monitoring by Centre Zero
Ammeter
-
Output A.C. Current Monitoring by Moving Iron Meter
-
Inverter bypass switch
-
To
extend operating time – suitable battery banks
-
Rack for mounting U.P.S. and batteries

Technical
Specifications
Output
Waveform
: Sinusoidal
Input
Voltage Range
: 180V to 260V (Switches over to battery)
Output
Voltage
: 230V +/- 2% (Nominal, can be modified)
Output
Frequency
: 50 Hz. +/- 0.1 Hz.
Harmonic Distortion
: Less than 5%
Capacity
: 250VA 500VA 1KVA
Current Capacity
: 1.0A 2.0A 4.0A
Battery Voltage
: 12V 24V 36V
Backup
Time (Approx.)
: 30 Mins. 30 Mins. 30 Mins.
Battery Recharge Time (Approx.)
: 6 Hrs. 8 Hrs. 14 Hrs.
Cooling (Air)
: Natural Natural Natural

Extra
Guarantee
We guarantee our products against manufacturing defects
for a period of 12 months from the date of original dispatch, provided
that the goods are returned to our works carriage paid.

Annual
Maintenance Contract
Offered by us for Post-Warranty period.
Prices and specifications are subject to change without notice.
Owing to our policy of continuous improvements instructions supplies may
differ in minor details from those described in this publication.
|